We use cookies to improve your online experience. By continuing browsing this website, we assume you agree our use of cookies.

Earthquake reduction effect of industrial large hanging fan pads

Views : 1600
Author : JU LAI
Update time : 2023-06-16 13:44:27

The earliest industrial large ceiling fans used reduction motors, and during the operation of the fan, the vibration of the blades generated a lot of noise. If used in a relatively quiet environment, it would cause users to feel irritable and bothered by the noise, resulting in dissatisfaction with the product quality and a negative impact on the manufacturer's reputation and public image. Therefore, installing rubber pads is essential to reduce the noise generated by large ceiling fans. By installing rubber shock absorber pads between the installation holes of the wheel hub and the shaped inserts, the non-rigid connection between the blade handle and the chassis wheel hub can be achieved, which can not only absorb most of the vibration from the blades but also improve the working conditions of the reduction motor shaft, extend the motor's service life, and make operation quieter.

Rubber pads have the characteristics of high elasticity, large elastic deformation, and small elastic modulus. The impact stiffness of rubber pads is greater than the dynamic stiffness, and the dynamic stiffness is greater than the static stiffness, which is beneficial to reducing impact deformation and dynamic deformation. Rubber shock absorber pads are made of incompressible materials, and their shape can be freely chosen. The hardness can be adjusted by formula design, which can meet the requirements of stiffness and strength in different directions.

Rubber pads can be divided into two types: molded and cut from a process perspective. Compared with cut rubber pad blocks, molded rubber pad blocks have higher overall precision and better appearance, but may be more expensive and require customization. The product cut from rubber is delivered faster. Although there may be slight deviations (2mm), it basically does not affect normal use, and the size can be arbitrarily cut.

Different choices of rubber pads also affect the production cost of industrial large ceiling fans. The service life of high-quality rubber pads can reach more than 5 years. The ease of installation of rubber shock absorber pads is equally important. When the shock-absorbing rubber sleeve ages, it only needs to be replaced with a new isolation pad without replacing other parts. Replacement is easy and reduces later maintenance costs. Moreover, when the rubber pads age, the shaped inserts can still prevent the up and down swing of the blades, which does not affect the overall safety of the large ceiling fan.

Related News
Read More >>
Advantages of Industrial Large Fans in Hot and Stuffy Environments Advantages of Industrial Large Fans in Hot and Stuffy Environments
Apr .01.2026
Industrial large fans are widely used in high-temperature and muggy environments. Their core advantages lie in comfortable cooling, efficient ventilation, and dehumidification and moisture prevention. They can provide a comfortable, safe and healthy environment for industrial settings, and are suitable for various large spaces such as workshops, warehouses and exhibition halls...
The core factors influencing the energy consumption of industrial large fans' motors The core factors influencing the energy consumption of industrial large fans' motors
Mar .04.2026
The energy consumption of industrial large fans' motors is influenced by multiple factors, which can be mainly classified into three categories: the performance of the motor itself, the operating conditions, and the usage environment. Reasonable control of these factors can significantly enhance energy efficiency and reduce operating costs. The performance of the motor itself is the foundation, and different types of motors have obvious differences in energy consumption...
How to Select an Industrial Large Fan Suitable for a Gym How to Select an Industrial Large Fan Suitable for a Gym
Feb .04.2026
First, pay attention to the size and air volume of the industrial large fan, which is the basis for adapting to the space of the gym. The size of the gym directly determines the choice of the fan. Generally, the diameter of the industrial large fan is positively correlated with the air volume and coverage area. The larger the diameter, the more sufficient the air volume it generates, and the wider the fitness area it can cover. When choosing, it is necessary to combine the actual area of the gym to ensure that the air volume of the fan can meet the overall ventilation needs, creating a refreshing and not stuffy exercise environment for members and avoiding the indoor stuffiness caused by insufficient ventilation...
Installing industrial fans in factories becomes a new choice for cost reduction and efficiency improvement Installing industrial fans in factories becomes a new choice for cost reduction and efficiency improvement
Jan .07.2026
With the upgrading of the manufacturing industry and the implementation of the "dual carbon" strategy, industrial plants have increasingly strict requirements for ventilation and cooling systems. The pain points of traditional ventilation equipment, such as high energy consumption and uneven coverage, urgently need to be solved. Industrial large fans (HVLS) have become the preferred solution for more and more enterprises to improve plant environments and reduce operating costs due to their prominent advantages of high energy efficiency, wide-area coverage, safety and reliability, injecting new vitality into industrial green production.