Installation of Industrial Large Fans (Part 2)

Views : 1637
Author : JU LAI
Update time : 2023-06-20 08:23:05

After all the preparations for the industrial ceiling fan are ready, let's learn about the detailed installation steps of the industrial ceiling fan on site:

  1. Install the base plate Install the base plate according to the installation position (marked by a line), with both sides evenly spaced, the base plate perpendicular to the installation beam, the top surface of the cushion plate closely attached to the I-beam, and the installation pressure plate combined with the I-beam. After installing the cushion plate flat, use M16*70 high-strength bolts for fixing, and other fixing methods to meet the same standards.
  2. Install the main unit Since the weight of the main unit of the fan is relatively large, special attention should be paid during installation. Use a level ruler to measure the verticality of the extension rod installation at 90 degrees. When the beam itself has a slope, its verticality can be adjusted through the crescent-shaped bolt holes of the base plate and the frame lifting ear. During installation, the upper plane and lower plane of the main unit should be horizontal, ensuring that the fan body naturally droops. Use a spirit level to measure and then tighten all fasteners (4 sets of M16 x140 high-strength bolts). M16x70 high-strength bolts, pressure plates, cushion plates, base plates, and I-beam steel beams, the cushion plate here needs to be closely attached to the I-beam, and if the thickness is not suitable, other auxiliary cushion plates need to be added to ensure that all parts are tightly pressed together. The bending part of the pressure plate here needs to be pressed against the cushion plate to avoid loosening. 
  3. Install the safety rope The steel wire rope goes around the factory beam to connect the fan main unit with the beam, and then use a wire rope clamp to strengthen the safety protection.
  4. Install the main rope First, determine the fixed positions around the four steel wire locks, move the lifting equipment to drill holes for positioning, and then start fixing the steel wire rope. Connect the main unit directly to the beam, and the steel wire should be of moderate length, equidistant, symmetrical, and evenly stressed. Adjust the fan's wheel hub to a horizontal position by tightening the four steel wire ropes. After the steel wire rope clamp and flower lacing wire are tightened, thread-locking glue (Loctite-243) should be applied to prevent the steel wire rope from loosening after being subjected to force.
  5. Install the cable connection of the main unit Do not scratch the surface of the cable wire, do not cut the copper wire when peeling the wire. First, connect the ground wire to black fine wire, and then use insulating tape to wrap it tightly to ensure the safety of the product. Then pull the cable out of the frame and wire it according to the on-site situation.
  6. Install the fan blades Two people cooperate to install the fan blades, using M10x60 high-strength countersunk bolts to fix the fan blades, diagonally install the fan blades, ensure even stress, do not scratch the surface of the fan blades, and ensure the tightness of the fasteners. After the fan blades are installed, the two steel wires passing through the interior of the fan blades are respectively threaded from bottom to top through the corresponding hinge bolt holes, and the two rope ends are combined at the upper part of the blade handle, and then fixed with corresponding steel wire rope clamps, and the excess part of the steel wire rope is cut off with a steel wire rope cutter.
  7. Install the fan blade safety ring When installing the fan blade connection plate, ensure that the rectangular hole is at the bottom and the round hole is at the top. Use M8x70 high-strength bolts to install them in order, and then form a circular shape to connect all the blades to each other. Finally, apply thread-locking glue to ensure the reliability of the fan operation. The above seven steps for installing an industrial ceiling fan are basically completed. Remember to pay attention to some detailed operations during installation. Any imperfection in detail may affect the stability and safety of the entire industrial ceiling fan system. At the same time, rigorous and meticulous training should be given to the installation team.
Related News
Read More >>
Advantages of Industrial Large Fans in Hot and Stuffy Environments Advantages of Industrial Large Fans in Hot and Stuffy Environments
Apr .01.2026
Industrial large fans are widely used in high-temperature and muggy environments. Their core advantages lie in comfortable cooling, efficient ventilation, and dehumidification and moisture prevention. They can provide a comfortable, safe and healthy environment for industrial settings, and are suitable for various large spaces such as workshops, warehouses and exhibition halls...
The core factors influencing the energy consumption of industrial large fans' motors The core factors influencing the energy consumption of industrial large fans' motors
Mar .04.2026
The energy consumption of industrial large fans' motors is influenced by multiple factors, which can be mainly classified into three categories: the performance of the motor itself, the operating conditions, and the usage environment. Reasonable control of these factors can significantly enhance energy efficiency and reduce operating costs. The performance of the motor itself is the foundation, and different types of motors have obvious differences in energy consumption...
How to Select an Industrial Large Fan Suitable for a Gym How to Select an Industrial Large Fan Suitable for a Gym
Feb .04.2026
First, pay attention to the size and air volume of the industrial large fan, which is the basis for adapting to the space of the gym. The size of the gym directly determines the choice of the fan. Generally, the diameter of the industrial large fan is positively correlated with the air volume and coverage area. The larger the diameter, the more sufficient the air volume it generates, and the wider the fitness area it can cover. When choosing, it is necessary to combine the actual area of the gym to ensure that the air volume of the fan can meet the overall ventilation needs, creating a refreshing and not stuffy exercise environment for members and avoiding the indoor stuffiness caused by insufficient ventilation...
Installing industrial fans in factories becomes a new choice for cost reduction and efficiency improvement Installing industrial fans in factories becomes a new choice for cost reduction and efficiency improvement
Jan .07.2026
With the upgrading of the manufacturing industry and the implementation of the "dual carbon" strategy, industrial plants have increasingly strict requirements for ventilation and cooling systems. The pain points of traditional ventilation equipment, such as high energy consumption and uneven coverage, urgently need to be solved. Industrial large fans (HVLS) have become the preferred solution for more and more enterprises to improve plant environments and reduce operating costs due to their prominent advantages of high energy efficiency, wide-area coverage, safety and reliability, injecting new vitality into industrial green production.