Wind pressure is important for industrial large fans

Views : 1746
Update time : 2023-06-16 13:21:11

then wind pressure is an important indicator to measure the "powerful" air volume of large fans. If air volume can be compared to the striking power of a weapon, then wind pressure is the sharpness of that weapon. Many clients who choose industrial fans consider air volume as the primary factor to consider. Wind pressure is one of the important performance indicators of large fans, and it is closely related to the shape, area, height, and speed of the fan blades. The impact of the first three is more complex, while the relationship with speed is simple and direct: the faster the speed, the larger the fan's airflow.

The wind pressure of industrial large fans changes with changes in airflow pressure. Wind pressure is caused by the obstruction of the building, which blocks the surrounding air, causing a drop in dynamic pressure and an increase in static pressure; this produces local eddies on the front and back sides. Compared with the disturbed airflow at a distance, the increase and decrease of static pressure are collectively called wind pressure. The wind pressure of a large fan is the pressure difference between the outlet and inlet of the fan. Its unit is generally mm (cm) water column, which is similar to measuring air pressure with a millimeter mercury column, but because the pressure difference is small, the water column is usually used as the unit: mmH20 / mmAq / Pa / mmHg.

To achieve normal ventilation, it is necessary to overcome the resistance within the ventilation path of the fan. The fan must generate pressure to overcome the resistance of air delivery. The change in measured pressure is called static pressure, which is the differential pressure between the maximum static pressure and atmospheric pressure. It is the pressure of gas acting parallel to the surface of an object. Static pressure is measured by a hole perpendicular to its surface. The wind pressure of an industrial fan directly affects the air delivery distance of the fan. The air volume and wind pressure described by large fans are both the maximum values under ideal conditions, that is, the air volume (maximum air volume) between the inlet and outlet of the industrial fan without pressure difference and the pressure difference (maximum static pressure) between the enclosed chamber where the fan blows air and the outside world when the air volume is zero. They are not two isolated performance indicators, but they restrict each other. The relationship between them is the typical relationship between flow velocity and pressure in fluid mechanics - as the pressure difference (specifically, the air resistance of the radiator fins) increases, the air volume decreases, and the degree to which they restrict each other depends on the design of blade shape and overall structure.

Industrial fan manufacturers consider both air volume and wind pressure in fan design. The fan blades of industrial large fans are designed with a streamlined variable cross-section design. When the fan is in operation, the blade can automatically rise by 3-8 degrees. When the fan stops, the blade can return to its original state. The fan has a diameter of 7.3 meters and rotates at 60 revolutions per minute. The design of blade shape, area, height, and fan speed can enable the industrial fan to achieve maximum air volume when in operation, reduce the central "hollow" phenomenon, and fully utilize the advantages of large air volume and wide coverage of large fans.

Related News
Read More >>
Advantages of Industrial Large Fans in Hot and Stuffy Environments Advantages of Industrial Large Fans in Hot and Stuffy Environments
Apr .01.2026
Industrial large fans are widely used in high-temperature and muggy environments. Their core advantages lie in comfortable cooling, efficient ventilation, and dehumidification and moisture prevention. They can provide a comfortable, safe and healthy environment for industrial settings, and are suitable for various large spaces such as workshops, warehouses and exhibition halls...
The core factors influencing the energy consumption of industrial large fans' motors The core factors influencing the energy consumption of industrial large fans' motors
Mar .04.2026
The energy consumption of industrial large fans' motors is influenced by multiple factors, which can be mainly classified into three categories: the performance of the motor itself, the operating conditions, and the usage environment. Reasonable control of these factors can significantly enhance energy efficiency and reduce operating costs. The performance of the motor itself is the foundation, and different types of motors have obvious differences in energy consumption...
How to Select an Industrial Large Fan Suitable for a Gym How to Select an Industrial Large Fan Suitable for a Gym
Feb .04.2026
First, pay attention to the size and air volume of the industrial large fan, which is the basis for adapting to the space of the gym. The size of the gym directly determines the choice of the fan. Generally, the diameter of the industrial large fan is positively correlated with the air volume and coverage area. The larger the diameter, the more sufficient the air volume it generates, and the wider the fitness area it can cover. When choosing, it is necessary to combine the actual area of the gym to ensure that the air volume of the fan can meet the overall ventilation needs, creating a refreshing and not stuffy exercise environment for members and avoiding the indoor stuffiness caused by insufficient ventilation...
Installing industrial fans in factories becomes a new choice for cost reduction and efficiency improvement Installing industrial fans in factories becomes a new choice for cost reduction and efficiency improvement
Jan .07.2026
With the upgrading of the manufacturing industry and the implementation of the "dual carbon" strategy, industrial plants have increasingly strict requirements for ventilation and cooling systems. The pain points of traditional ventilation equipment, such as high energy consumption and uneven coverage, urgently need to be solved. Industrial large fans (HVLS) have become the preferred solution for more and more enterprises to improve plant environments and reduce operating costs due to their prominent advantages of high energy efficiency, wide-area coverage, safety and reliability, injecting new vitality into industrial green production.